Download Agilent E3620a Service Manual

  
Agilent 34972a User Manual

• Manual Part No. • SAFETY SUMMARY. • The Change Sheet may also contain information for correcting errors in the manual.

Agilent E3630a User Manual View and Download Agilent Technologies E3634A, E3633A service manual Power Supply Agilent. Agilent E3620a Manual How to. View and Download Agilent Technologies E3620A operating and service manual online. DUAL OUTPUT POWER SUPPLY. Operation and service Manual.

This section contains general information concerning the E3630A triple output power supply. Included are safety con- Options OE3 and OE9 determine which line voltage is siderations, safety and EMC requirements, instrument and selected at the factory. In this mode the voltage of the negative output can be set are available for nominal inputs of 100 and 230 Vac. The sup- lower than that of the positive output. The tracking ratio control ply is furnished with a detachable 3-wire grounding type line allows the negative supply's output to be set to any value cord. • Save all packing materials until the inspection is completed.

If damage is found, a claim should be filed with the carrier. The Agilent Technologies Sales and Service office should be notified as soon as possible. This check should confirm that there are no broken knobs. • tor the 0 to 40V output voltage, add the voltmeter readings of the +20V and -20V output and use either the +20V or the - 20V meter to measure the current. With the Tracking Ratio control in the Fixed position, the volt- age of the -20V supply tracks that of the +20V supply within 1% for convenience in varying the symmetrical voltages needed by operational amplifiers and other circuits using bal.

• LOAD CONSIDERATIONS Figure 3. Current Limit Characteristic of the 6V Supply. Reverse Current Loading Solution. • SERVICE INFORMATION Figure A-1. Msn Icq Smiley Pack.

Block Diagram PRINCIPLES OF OPERATION (Block Diagram Overview) • MAINTENANCE Test Equipment Required. Test Equipment Required (Cont’d) Current Sampling 100 mΩ 0.1% 15 W Measure output current Resistor (Shunt) Variable Voltage Range: 85-130 and 200-260 Vary ac input. Auto Transformer Volts Operation Verification Tests General Measurement Techniques The following tests assure that the power supply is per- forming properly. • Current Limit Line Regulation (Source Effect) k. Game Of Thrones Season 5 Hdtv. Disconnect all loads from the supply. Definition: The change, E, in the static value of dc output Connect the test setup shown in Figure A-5 to the +20- voltage resulting from a change in ac input voltage from a volt output. • Figure A-8.

Load Transient Response Time Waveform. • Definition: TROUBLESHOOTING. • ADJUSTMENT AND CALIBRATION. • REPLACEABLE PARTS.

• 6CDNG #  4GRNCEGCDNG 2CTVU.KUV MFR. P/N REFERENCE PART Q'TY DESCRIPTION MFR. CODE DESIGNATION NUMBER. • REFERENCE PART Q'TY DESCRIPTION MFR.

P/N DESIGNATION NUMBER. • REFERENCE PART Q'TY DESCRIPTION MFR. P/N DESIGNATION NUMBER /+5%'.#0'175. • REFERENCE PART Q'TY DESCRIPTION MFR. P/N DESIGNATION NUMBER. • DECLARATION OF CONFORMITY.